Monitors > Accuit Sign 7

 

The Accuit Sign series is designed for the most intense ICU and General environment. With its Crystal clear LCD screen and easy to read display, you can rest easy knowing you're getting the most clear and optimum readings.

With over 15 years of evolution, the Accuit Sign series of Patient monitors are the pinacle of modern monitoring technology. It has a full range of features including Heart rate monitoring, NIBP, Respitory rate, ECG, SpO2 and temperature sensors which give the complete picture of the patients condition.

Simply put, the Accuit Sign series are the staple for every Hospital.


Download Brochure Here

  • Feature:
    High resolution 12.1"color TFT display
    Suitable for adult, pediatric and neonatal patient
    Color TFT Screen, waveform up to 8 channels
    Operation modes: Diagnostic, Monitor, Surgery
    Light and portable with Built-in rechargeable lithium battery
     UP to 10 kinds of monitor parameters
     Arrhythmia analysis, pace-marker detection and S-T Segment analysis
    72 hour storage and review of trend grams and tables
    500 NIBP measurement date can be storage and recall
    Electro surgical unit and defibrillation protected
    Networkable with central monitoring system
    Standard parameters: ECG, NIBP, SPO2, Respiration, Temperature, Pulse rate, Thermal Printer, CO2, IBP
    ECG
    5-lead or 3-lead selectable
    Input: 5-lead :RA; LA; RL; LL; V or R; L; N; F; C
    ECG waveforms of 7-leads display on the same screen
    Lead selection :I; II; III; avR; avL; avF; Vx
    ECG waveform :2 channels
    Gain selection :12.5mm/s, 25mm/s, 50mm/s
    Accuracy :±1bpm or ±1%, whichever is greater
    Protection :Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
    Calibration signal :1mV±5%
    Alarm range: Adult :15-300bpm
    Pediatric/Neonatal :15-350bpm
    Arrhythmia analysis and S-T segment analysis

    Alarm range

    :-2.0mV~2.0mV
    S-T segment detection Measurement rang :-0.2mv~2.0mv
    Alarm :Yes, audible and visual alarm, alarm events review
    NIBP
    Operation modes :Manual/Automatic/STAT
    Measurement unit :mmHg/KPa selectable
    Measurement types :Systolic, Diastolic and Mean
    Over-pressure protection :YES
    Resolution :1mmHg
    Accuracy :Mean error and standard deviation per ANSI/AAMI SP-10
    Alarm :Systolic, Diastolic, and Mean
    Auto measure time :Adjustable
    Measurement rang :10-270mmHg
    500 NIBP measurement date can be storage and recall
    SpO2
    Measurement range :0-100%
    Accuracy :70-100%, ±2% 0-69%, upspecified
    Alarm range :0-100% Pulse rate
    Range :20-254bpm
    Accuracy :±3bpm
    Respiration
    Method :RA-LL impedance
    Pediatric/Neonatal :6-150rpm
    Alarm range: Adult :6-120rpm
    Pediatric/Neonatal :6-120rpm
    Apnea alarm :YES
    Temperature
    Channel :Dual-channel
    Alarm range :0-50℃
    Apnea :0.1℃
    CO2
    Method :Thermo-dilution
    Measurement range :CO: 0.1-20 lit /min.
    IBP
    Channel :2 channels
    Pressure transducer :Sensitivity: 5(mV/V/mmHg)
    Transducer sites :ART, PA, CVP, RAP, LAP, ICP
    Alarm range :-10~300mmHg
    Standard Accessories:
    ECG, SPO2, NIBP, 1- Skin TEMP
    Optional Accessories:
    IBP, CO2