The Oxi Check series is designed for the most intense ICU and General environment. With its Crystal clear' LED screen and easy to read display, you can rest easy knowing you're getting the most clear and optimum readings.

With over 15 years of evolution, the Accuit Sign series of Patient monitors are the pinacle of modern monitoring technology. It has a full range of features including Heart rate monitoring & SpO2 which give the complete picture of the patients condition.

Simply put, the OxiCheck is a staple for every Hospital.


Download Brochure Here

Patient Monitor adopts Oscillometry for NIBP measuring, Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. SpO2 and Pulse rate(PR) can be accurately measured.
Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for hospitals, community medical treatment and family.
Features
■Is applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.
■Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.
■Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
■Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.
■With user-friendly interface.
■Display with 2.4'' (320×240) color TFT LCD and bright highlight LED.
■Convenient and quick in inquiring measurement data.

SpO2 monitoring 
■Continuous real-time measuring.
■Adopt digital SpO2 technology, which has strong anti-interference capability.
■Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
■Trend graph with the function of adaptive scaling
■Standard adult finger-clip probe, binding probe for neonatal is optional.
SpO2 Measuring
Range: 35%~100% (Resolution: 1%)
Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.
 Pulse Rate Measuring
 Range: 30bpm~250bpm(Resolution: 1bpm)
 Accuracy: ±2bpm or ±2%, whichever is greater.
 Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown 
correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
 Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Accessories
■A power cord
■A SpO2 probe